PROBLENDER 1000 NITROX BLENDER

NTS
€3,270.00

The best solution to blend Nitrox while emptying B50 safety. Allows to blend any Nitrox up to 40 % of O2. The technique consists in mixing the Nitrox before passing it through the compressor. It is for this reason that we can not exceed 40 % of O2.

PROBLENDER 1000 TRIMIX BLENDER

NTS
€4,786.00

The solution to mix Nitrox, Trimix, Triox and Héliox while emptying B50. Allows to mix any Nitrox, Trimix, Triox and Héliox having a maximal rate of 40% of O2. The technic consists in making Nitrox, Trimix, Triox or Héliox before compressing it by the mean of the compressor. That is why we must not exceed 40% of O2.

AIR/O2 SURFACE PRESSURE GAUGE DIN 200/300 B

TDS

Surface gauge for checking pressure out of the water bottles. DIN system. Purge by knob. Dial easy to read. Scale up to 400 bar. Is clean for use with oxygen, but if used with air the O2 service is lost.

OXYGEN METALIC DECANTING HOSE W/PRESSURE GAUGE

TDS

Metalic decanting device for oxygen. Purge tap. With pressure gauge to control the amount of transferred gas. DIN 200/300 connections at both ends. Hose length 2 m approx.

AIR/OXYGEN METALIC DECANTING HOSE DIGITAL...

TDS

TDS Oxygen & Air Metalic decanting hose with digital pressure gauge and valve for technical scuba diving: TDS Metalic decanting device for oxygen, with relieving pressure valve, 100 mm hose, digital pressure gauge and DIN 200/300 filling connection at both sides.

OXYGEN METALIC DECANTING HOSE DIGITAL PRESSURE...

TDS

TDS Oxygen metalic decanting hose with digital pressure gauge and valve: TDS Metalic decanting device for oxygen, with relieving pressure valve, 100 mm hose, digital pressure gauge and DIN 200/300 filling connection at both sides.

OXYGEN 300 BAR NEVOC CONECTION W 30x2

TDS

Oxygen cylinder connection 300 B (W 30x2). With coupling to DIN 200/300 allows oxygen transfer oxygen cylinders with 300 bar DIN connections transfer device 200 or 300Oxygen cylinder connection 300 B (W 30x2). With coupling to DIN 200/300 allows oxygen transfer oxygen cylinders with 300 bar DIN connections transfer device 200 or 300

HELIUM 300 BAR NEVOC CONECTION W 30x2

TDS

Oxygen cylinder connection 300 B (W 30x2). With coupling to DIN 200/300 allows oxygen transfer oxygen cylinders with 300 bar DIN connections transfer device 200 or 300Oxygen cylinder connection 300 B (W 30x2). With coupling to DIN 200/300 allows oxygen transfer oxygen cylinders with 300 bar DIN connections transfer device 200 or 300

OXYGEN CGA TO G1/4 MALE ADAPTOR

TDS

CGA 540 Oxygen cylinder connection to G1/4 male. With coupling to DIN 200/300 allows oxygen transfer from oxygen cylinders decanting device 200 or 300 (sold separately, see related products below)

HELIUM CGA TO G1/4 MALE ADAPTOR

TDS

CGA 580 Helium cylinder connection to G1/4 male. With coupling to DIN 200/300 allows helium transfer from cylinders with decanting device 200 or 300 (sold separately, see related products below)

DRAGUER FEMALE TO G1/4 MALE ADAPTOR

TDS

Draguer female cylinder connection to G1/4 male. With coupling to DIN 200/300 allows decanting from cylinders with decanting device 200 or 300 (sold separately, see related products below)

G3/4 FEMALE TO G1/4 MALE ADAPTOR

TDS

G3/4 female (german oxygen cylinders) connection to G1/4 male. With coupling to DIN 200/300 allows decanting from cylinders with decanting device 200 or 300 (sold separately, see related products below)

300 BAR HELIUM/OXYGEN NEVOC ADAPTER CONNECTOR...

TDS

TDS Coupling for connecting 300 bar Oxygen/Helium Nevoc conections (sold separately, see related products below) to female DIN 232. Allows to connect equalizer hoses DIN 200/232 to 300 Bar Helioum or Oxygen cylinders.

300 BAR HELIUM/OXYGEN NEVOC ADAPTER CONNECTOR...

TDS

TDS Coupling for connecting 300 bar Oxygen/Helium Nevoc conections (sold separately, see related products below) to female DIN 300. Allows to connect equalizer hoses DIN 300 to 300 Bar Helioum or Oxygen cylinders.

MALE DIN 200 G5/8 TO FEMALE M26 CONVERTER

APD
€35.00
For gas-filling when travelling in Europe and/or adapting a 5/8" BSP cylinder valve to accept a M26x2 first stage or compressor connector

MALE M26 TO DIN 200 G5/8 FEMALE CONVERTER

APD
€40.00 -20% €32.00
For gas-filling when travelling in Europe and/or adapting an M26x2 cylinder valve to accept a 5/8" BSP first stage, compressor connector or O2 whip
  • -20%

DIN 232 TO OXYGEN CONVERTER

TECNOMAR
€71.00 -20% €56.80

Converting fitting part from conical oxygen cylinder to G 5/8 "DIN standard thread 232 bar. Allows to connect normal equalizer hoses to oxygen cylinder for filling and transfer gas.

  • -20%

G1/4 MALE TO G1/4 FEMALE CONNECTOR

TDS

TDS Coupling for connecting G1/4 threads. For decanting hoses connections. Allows the connection between decanting hoses. Also valid for HP Booster connections.

G1/4 MALE TO G1/4 CONIC MALE CONNECTOR

TDS

TDS Coupling for connecting G1/4 threads. For decanting hoses connections. Allows the connection between decanting hoses. Also valid for HP Booster connections.

OXYGEN 300 BAR CONECTION W 30x2 (Ref 1134)

TECNOMAR
€100.00 -10% €90.00
Oxygen cylinder connection 300 B (W 30x2). With coupling to DIN 200/300 allows oxygen transfer oxygen cylinders with 300 bar DIN connections transfer device 200 or 300Oxygen cylinder connection 300 B (W 30x2). With coupling to DIN 200/300 allows oxygen transfer oxygen cylinders with 300 bar DIN connections transfer device 200 or 300
  • -10%

NITROX TANK DECAL

TDS

TDS Nitrox Scuba Diving Tank Decal: Tds nitrox identification sticker to put on bottles Nitrox tanks and make a perfect identification and distinction from other bottles. Dimensions 60 cm x 15 cm

LP 250 NITROX ROTARY

COLTRI

Coltri LP250 Nitrox ROTARY for Scuba Diving: It consists of an industrial screw compressor that delivers air at a pressure of 10 bar to the Parker® membrane. The percentage of oxygen obtained at the outlet can be adjusted from 32% to 36% thanks to a valve accessible on the front side of the compressor. If connected to a compressor with pumping unit 315 (MCH 16), Nitrox at 32% can be obtained up to a pressure of 232 bar. The oxygen analyzer allows you to check the correct percentage, adjusting it through the appropriate valve.

LP 300 NITROX ROTARY

COLTRI

The Coltri LP300 Nitrox ROTARY model consists of an industrial screw compressor that delivers air at a pressure of 12 bar to a membrane that separates nitrogen and oxygen up to a maximum percentage of 40% O2. The enriched air can be compressed at a pressure of 232 bar in combination with a high pressure compressor. The percentage of oxygen obtained at the outlet can be regulated from 22.4% to 40% using a valve directly accessible on top of the compressor. The oxygen analyser allows checking of the correct percentage adjusted by means of the appropriate valve.