Utilizamos Cookies propias y de terceros para recopilar información para mejorar nuestros servicios y para análisis de tus hábitos de navegación. Si continuas navegando, supone la aceptación de la instalación de las mismas. Puedes configurar tu navegador para impedir su instalación.
Compulsory cookies
Always active
Cookies that are strictly necessary to provide a service or content requested by the user. These are responsible for technical aspects such as identifying records and managing tool preferences for the use, interaction and location of access to content.
Cookies used
Functional cookies
Functional cookies give the user information that make their browsing experience richer, such as, for example, displaying the weather forecast based on their location.
Cookies used
Statistical/analytical cookies
These cookies collect information related to website use, such as the time spent on it and the content visited by readers, to measure its performance and improve navigation.
Cookies used
Advertising and third-party customization cookies
These cookies obtain information from user browsing to manage advertising space and offer more relevant and quality content for them based on their preferences.
Cookies used
Se informa al usuario de que tiene la posibilidad de configurar su navegador de modo que se le informe de la recepción de cookies, pudiendo, si así lo desea, impedir que sean instaladas en su disco duro.
A continuación le proporcionamos los enlaces de diversos navegadores, a través de los cuales podrá realizar dicha configuración:
Description: For gas-filling when travelling in Europe and/or adapting an M26x2 cylinder valve to accept a 5/8" BSP first stage, compressor connector or O2 whip European Standard for oxygen connection - applies from August 2008 The European...Description:
For gas-filling when travelling in Europe and/or adapting an M26x2 cylinder valve to accept a 5/8" BSP first stage, compressor connector or O2 whip
European Standard for oxygen connection - applies from August 2008
The European standard came into force in August 2008 specifying that the connection to a cylinder containing any gas with an oxygen percentage greater than 22% should be a different thread (M26x2) than the BSP thread standard on air cylinders
As a result, from July 2008, we modified the connection on the oxygen cylinder valve (and the AP oxygen first stage) of all AP rebreather onboard cylinders to the new M26x2 thread as our standard production spec
In order to overcome possible difficulties with compatibility on existing dive kit and issues with filling cylinders, we have introduced the two adaptors (AP8N and AP8R) allowing the conversion of the (pre-July 2008) 5/8" BSP thread to the new M26x2 thread and vice versa
Customers will still be able to specify the valve (and first stage) with 5/8" BSP thread on all new unit orders, allowing customers outside the EU to purchase the valve they have always used but also allowing customers within the EU that may travel frequently to purchase the most appropriate valve for their most common diving destinations
NOTE: If a valve choice is not specified the default valve supplied will have the new M26x2 thread
View more
Hello, I'm David. Do you need help?
Our experts have helped over 100,000 people make a decision.